How To Calculate Time Required For Flash Distillation
Welcome
curious minds!
In batch
flash distillation, it is tempting to calculate the required time simply from
the amount of solvent and its latent heat:
t = m × λ /
Qavailable
This gives
a useful first estimate—but it can be misleading. The reason is simple; reactor
does not spend all the supplied heat on vaporizing the solvent.
Before and
during distillation, heat is also used to heat the reaction mass, reactor metal
and internals, while some heat is continuously lost to the surrounding.
The total
heat supplied to the system can be considered as:
Q total
= Q sensible + Q metal + Q latent + Q loss
Where:
Q sensible
= heat required to raise the reaction mass to the distillation temperature
Q metal
= heat required to heat the reactor, agitator, coils, baffles and other metal
parts
Q latent
= heat required to vaporize the solvent
Q loss
= heat continuously lost to the surroundings
This is why
the actual batch time can be significantly higher than a calculation based only
on latent heat.
Let's
understand this with an example, consider a reactor containing a reaction mass
from which toluene is to be removed by flash distillation. Process data for the
distillation is mentioned as below.
Reactor volume:
Reaction mass
volume: consider
reaction mass density 1100 Kg/m3
Solvent to
distilled: Toluene ()
Density of toluene:
(
)
Mass of toluene
():
Specific
Heat of Reaction Mass ():
Boiling
Point of Toluene ():
Latent Heat
of Vaporization ():
Vessel/Jacket
Temperature ():
Initial
Temperature (): consider
Reactor
MOC- SS316, reactor ID dia.- 1800 mm and shell length-2000 mm consider 10% tori
spherical dish end reactor. Dish end thickness -10 mm, reactor shell Thickness
=
Reactor occupancy is calculated as,
Bottom dish volume = 0.1 x (1.8)3 =
0.58 m3
Reaction mass in shell volume would be =
4-0.58 = 3.42 m3
Reactor occupancy = (3.42/5) x100 = 68.4 %
Shell HTA
available = π x 1.8 x 2 = 11.3 m2
dish end
area = 1.11 x (π/4) x (1.8)2 = 2.82 m2
Total HTA
available = 11.3 +2.82 = 14.12 m2
Actual HTA
available as per reactor occupancy = 11.429 x 68.4% = 9.65 m2
Reactor
shell weight is calculated as,
Shell
weight =πx OD x L x t x ρ metal= π x 1.808 x 2 x 0.008 x 8000 = 727 Kgs
Reactor dish
end thickness is calculated as,
Blank Dia
(Db) = OD+ (OD/42) +( 2 x SF) +( 2/3 x Kr)
Consider SF
= 50 mm and
Knuckle
radius (Kr) = 0.1 x OD = 0.1x1820 = 182 mm (for 10% torispherical dishend)
Blank Dia
(Db) = 1.82 + (1.82/42) +(2 x 0.05) +(2/3 x 0.182) =2.085 mtr
Dish end
C/s area = (π/4) x 2.0852= 3.412 m2
Dish end
weight = 3.412 x 0.01x 8000 = 273 kg
For top and
bottom dish end weight would be = 2 x 273 = 546 kgs
Jacket MOC
MS and jacket thickness is 10 mm and in general jacket length is 80% of shell
length and shell OD to jacket annular gap maintained is 50 mm
So, Jacket
ID is = 1820+50+50 = 1920 mm and Jacket OD is 1940 mm
Jacket
length is =2000 x 0.8 = 1600 mm
Jacket
Shell weight = π x 1.93 x 1.6 x 0.01 x
7850 = 761.5 kg
Jacket dish
end blank dia. (Dbj) = 1.94 +(1.94/42 )+(2 x0.05 )+ (2/3 x 0.194) = 2.216 mtr
Jacket dish
end C/s area = (π/4) x 2.2162= 3.854 m2
Jacket
weight = 3.854 x 0.01 x 7850 = 302.6 kg
Total
reactor weight = 727 +546 +761.5 +302.6 = 2336.6 kg
Consider
10% excess weight to include nozzles manhole and jacket closure plate weight
Final
reactor weight = 2336.36 x 1.1 = 2570 kg
Sensible
heat rise of reaction mass = 110.6 -30 = 80.6 oC
Sensible
heat required to heat reaction mass Q1 = 4 x 1100 x 0.476 x 80.6 = 168808 kcal
SS 316
specific heat is 0.12 kcal/kg oC
Sensible
heat required to raise metal temp Q2 = 2336.6 x 0.12 x 80.6 =22600 kcal
Latent heat
required for toluene flash distillation Q3 = 1000 x 86.1 =86100 kcal
Total heat
input Q = Q1 +Q2 + Q3 = 168808 + 22600 +86100 = 277508 kcal
Consider
10% heat loss from surface insulation
Net heat
input is Q = 277508 x 1.1 = 305259 kcal
Net temp
difference available is 125 -110.6 = 14.4 oC
U for reactor is 300 Kcal/Hr m2 oC
( ref example solved in OHTC calculation blog)
Q = U x A x
ΔT x t
305259 = 300
x 9.65 x 14.4 x t
Time
required for distillation (t) = 7.3 Hr
So, the
estimated flash-distillation time is approximately 7–7.5 hours under the stated
assumptions.
If we
considered only the energy required to vaporize the toluene:
t = 86,100
/ (300 x 9.65 x14.4) ≈ 2.1 hours
But the
reactor cannot reach the distillation condition instantly.
A
significant amount of energy is first required to heat the reaction mass and
reactor metal. Heat losses also continue throughout the operation.
This is the
key reason why a 2.1-hour latent-heat estimate can become a roughly 7-hour
practical heating requirement in this example.
Learn. Understand. Apply. Engineer.
Happy reading!

Comments