Steam properties: Quick calculation using thumb rules
Welcome curious minds!
In chemical and process industries, heating is required almost
everywhere—reactors, evaporators, reboilers, dryers and heat exchangers.
Different heating media can be used, such as steam, thermic fluid,
hot water and electrical heating. Among these, steam is one of the most widely
used because it can deliver a large amount of heat through condensation at
nearly constant temperature.
Why is steam an excellent heating medium?
1. High heat release through condensation-The
biggest advantage of saturated steam is its latent heat. At atmospheric
pressure, saturated steam releases approximately; hfg ≈ 539 kcal/kg
2. Nearly constant heating temperature- When
saturated steam condenses, heat is released at approximately its saturation
temperature.
3. High heat-transfer coefficient-Condensing
steam generally provides a much higher heat-transfer coefficient than many
liquid heating media.
4. Easy temperature control-For saturated steam, pressure and
saturation temperature are directly related. Therefore, changing the steam
pressure changes the available heating temperature.
5. Convenient distribution-Steam is generated centrally and
distributed through a piping network to multiple process users.
6. Condensate can be recovered- After transferring its latent heat,
steam becomes condensate. Instead of wasting this hot condensate, it can be
collected and returned to the boiler system.
For detailed design, equipment sizing and safety-critical
calculations, steam tables, IAPWS-based property data or process simulation
software should be used.
But during preliminary calculations, troubleshooting or quick
checks, simple thumb rules are extremely useful.
Let us take an example and calculate steam properties using thumb
rules. Consider, 4 barg saturated steam, we will estimate; saturation
temperature, steam density, specific volume, steam enthalpy, sensible heat and
latent heat
Let us solve using thumb rules,
Pabs = Pgauge + 1
Therefore: Pabs = 4 + 1 = 5 bar(a)
A useful approximate relationship for saturated steam is; Tsat
(°C) = 100 × Pabs⁰·²⁵
Therefore; Tsat = 100 × (5)⁰·²⁵ ≈ 149.5°C
For a quick approximation, saturated steam can be treated
approximately as an ideal gas.
The equation is, ρ = PM / RT
Where:ρ = steam density, kg/m³
P = absolute pressure, bar
M = molecular weight of water vapour =
18 kg/kmol
R = 0.08314 bar·m³/(kmol·K)
T = absolute temperature, K
Temperature; T = 149.5 + 273.15 = 422.65 K
Therefore; ρ = (5 × 18) / (0.08314 × 422.65) ≈ 2.57 kg/m³
Specific volume is simply the inverse of density; v = 1 / ρ
Therefore: v = 1 / 2.57 ≈ 0.389 m³/kg
For a quick industrial estimate, saturated-steam enthalpy can be
approximated as:
hg ≈ 610 + 0.3T
where T is in °C and hg is in kcal/kg.
Therefore; hg = 610 + (0.3 × 149.5) ≈ 654.9 kcal/kg
For a rough estimate sensible heat of condensate is; hf ≈ T
Therefore; hf ≈ 149.5 kcal/kg
We know,
Steam Enthalpy (hg) = Steam condensate sensible heat (hf)+ Latent heat(hfg)Therefore; hfg = hg − hf
So; hfg = 654.9 − 149.5≈ 505.4 kcal/kg
Alternatively, combining the above thumb rules:
hfg ≈ 610 − 0.7T
Therefore; hfg ≈ 610 − (0.7 × 149.5) ≈ 505.4 kcal/kg
Let us compare steam properties calculated by thumb rules with
steam table values,
|
Parameter |
Steam
Table |
Thumb
Rule |
|
Steam
pressure |
4 barg |
4 barg |
|
Saturation
temperature |
151.8°C |
149.5°C |
|
Density |
2.67
kg/m³ |
2.57
kg/m³ |
|
Specific
volume |
0.374
m³/kg |
0.389
m³/kg |
|
Steam
enthalpy, hg |
656.4
kcal/kg |
654.9
kcal/kg |
|
Liquid
enthalpy, hf |
152.9
kcal/kg |
149.5
kcal/kg |
|
Latent
heat, hfg |
503.5
kcal/kg |
505.4
kcal/kg |
The comparison shows that the thumb rules provide a reasonable
first approximation values.
You don't always need a steam table for a quick engineering
estimate.
Understand the principle, remember the shortcut, and verify the
final design with reliable steam-property data.
Happy reading!
Insightful content