Flash steam recovery using Thermocompressor: working principle & design calculation

Flash Steam Recovery System

Welcome curious minds!

        One of the common and unfortunate sights in many steam-using industrial plants is a visible plume of steam escaping from condensate recovery systems, flash tanks, vents, or process equipment.

That plume represents more than just visible water vapour—it can represent a significant loss of recoverable thermal energy.

Steam generation is expensive, and therefore any opportunity to recover and reuse flash steam can improve overall plant energy efficiency, reduce boiler fuel consumption, and lower operating costs.

One effective method of recovering low-pressure flash steam is to use a thermocompressor, also known as a steam ejector.

This article explains the principle of flash steam generation and demonstrates, with an example calculation, how flash steam can be recovered and recompressed for reuse in a process heating application.

Flash steam is the steam generated when hot condensate is discharged from a higher pressure to a lower pressure.

The principle is straightforward.

When pressure is reduced, the saturation temperature of water also decreases. Therefore, condensate that was at a high pressure contains more sensible heat than is required to remain as saturated liquid at the lower pressure.

The excess sensible heat causes a portion of the condensate to evaporate or flash into steam.

% Flash steam generation from condensate is calculated as,

% Flash steam generation = (hf1 -hf2)/ hfg2 x 100

hf1 - Sensible heat (enthalpy) of saturated liquid at the initial high pressure before flashing (kcal/kg or Btu/lb)

hf2 - Sensible heat (enthalpy) of saturated liquid at the lower flash pressure (kcal/kg or Btu/lb).

hfg2 - Latent heat of vaporization at the lower flash pressure (kcal/kg or Btu/lb)

Just multiply % Flash steam generation with condensate flow to get flash steam generation from condensate in Kg/Hr.

Why should flash steam be recovered?

Flash steam is normally produced at a relatively low pressure.If this steam is simply vented to atmosphere, its useful thermal energy is lost.In some applications, the flash steam pressure is also too low to provide the required temperature difference for the downstream heating process.

A thermocompressor can solve this problem.

A thermocompressor uses high-pressure motive steam to entrain low-pressure flash steam and compress the resulting mixture to an intermediate pressure.The recovered steam can then be reused in process heating.

The basic arrangement is:

High-pressure motive steam + low-pressure flash steam → thermocompressor → intermediate-pressure steam

This is an attractive method of energy recovery because part of the low-pressure steam that would otherwise be wasted becomes useful process steam.A thermocompressor operates on the ejector principle.

High-pressure motive steam enters a specially designed nozzle and expands to a high velocity.The resulting low-pressure region at the nozzle outlet draws in the flash steam.

The motive steam and suction steam then mix, and the mixed flow is decelerated in the diffuser. The velocity energy is converted into static pressure.As a result, the thermocompressor produces steam at a pressure higher than the original flash-steam pressure.

The three important operating pressures are:

  • Motive steam pressure, (Pm)
  • Suction steam pressure, (Ps)
  • Discharge steam pressure, (Pd)

The quantity of motive steam required depends strongly on the pressure conditions and the thermocompressor design.

Important thermocompressor parametes

 Entrainment Ratio: Ratio of suction (flash) steam mass flow to motive (high-pressure) steam mass flow.

   Entrainment ratio = mflash / mmotive

A higher entrainment ratio means that less motive steam is required for a given suction-steam flow.

However, the entrainment ratio is not a fixed universal value. It must be obtained from a thermocompressor performance curve, manufacturer data, or a validated ejector design calculation for the specified operating conditions.

 Compression Ratio: Ratio of discharge (mixture) pressure to suction (flash) pressure.

Let us solve the example to understand above mentioned concepts.

Consider the following process conditions:

  • Condensate pressure = 7.5 barg
  • Condensate flow = 5,000 kg/h
  • Flash pressure = 0.6 barg
  • Motive steam pressure = 7.5 barg
  • Required thermocompressor discharge pressure = 2.5 barg
The objective is to determine:
  1. Flash steam generated
  2. Motive steam required
  3. Total steam available at the thermocompressor discharge

Let us solve this example, Find condensate and flash steam enthalpy from steam table,

Enthalpy of 7.5 barg condensate (hf1) = 175.12 Kcal/Kg

Enthalpy of 0.6 barg condensate (hf2  ) = 115.82 Kcal/Kg

Latent heat of 0.6 barg steam(hfg2 ) = 530.37 Kcal/Kg

% Flash steam = (hf1 -hf2)/ hfg2 x 100 = ((175.12 -115.82)/530.37) x 100 = 11.1 %

Flash steam generation = % flash steam x condensate flow rate

                                           = 11.1% x 5000 = 555 kg/Hr

Condensate recycled back to boiler feed = 5000 – 545 = 4445 kg/Hr

Let us check thermocompressor  design,

Thermocompressor suction pressure (Ps) = 0.6+1= 1.6 bara

Thermocompressor motive pressure (Pm) = 7.5 + 1 = 8.5 bar a

Thermocompressor discharge pressure (Pd) = 2.5+1= 3.5  bara

Thermo compressor  compression ratio = 3.5/1.6 = 2.187

Suction to motive ratio (Ps/Pm) = 1.6/ 8.5 = 0.188 =0.19

Let us check it  from single stage ejector graph attached below for calculated compression ratio and suction to motive ratio  A1/A2 =3.8.

Design Curve For Single Stage Ejector

And entrainment ratio derived from graph is 0.27

Therefore motive steam required to compress flash steam is

    Motive steam required = 555/0.27 = 2018.5 Kg/Hr

 And low pressure steam available at discharge would be

   Low pressure generated = 555+2018.5 = 2573.5  kg/Hr

The benefit is that the 555 kg/h of low-pressure steam, which may otherwise be vented or underutilized, is recovered and upgraded to a pressure suitable for the process.

 Happy reading!