Agitator scale-up techniques – Part 2

 

Agitator Scale-up

Welcome curious minds!

In Part-1, we discussed the basic principles of agitator scale-up and saw how criteria such as geometric similarity, constant tip speed, constant torque per unit volume, and constant power per unit volume can be used to move from a pilot reactor to a commercial reactor.

But there is an important question that often comes next; which scale-up criterion should actually be used?

This is where agitator scale-up becomes more than just a mathematical exercise.

A reactor may need fast blending, good surface circulation, mass transfer, solids suspension, gas dispersion, or controlled shear. These objectives do not respond to agitator speed in the same way.

Therefore, instead of simply saying “increase the vessel size and reduce the rpm,” engineers often use a scale-up exponent to select an appropriate agitator speed.

For geometrically similar vessels, agitator speed can be expressed in the general form:

N2/N1= (Da1/Da2) x

Where; N1 - agitator speed at pilot scale

N2- agitator speed at commercial scale

Da1- pilot impeller diameter

Da2- commercial impeller diameter

X - scale-up exponent

The value of x depends on what we are trying to preserve during scale-up.

This is the key idea; different process objectives require different relationships between impeller diameter and agitator speed.

How does the exponent change the agitator speed?

For the same increase in impeller diameter, changing x can produce a very different commercial agitator speed.

Typical preliminary values are:

Process objective

Scale-up basis

Exponent x

Blending / mixing time

Constant N

0

Surface behaviour

Constant Froude number

1/2

Mass transfer / droplet size

Constant power per unit volume

2/3

Solids suspension

Empirical suspension criterion

3/4

Constant tip speed

Constant NDa

1

 

1. Blending: constant agitator speed

For some blending applications, a simplified scale-up approach is to maintain the same agitator speed; N2=N1. Therefore; x=0

However, keeping the same rpm as vessel size increases can significantly increase tip speed, power demand, and mechanical loading. Therefore, it should not be applied blindly.

2. Surface behaviour: Constant Froude number

When free-surface behaviour is important, such as in systems where surface vortex formation or surface movement matters, the Froude number can be considered, Fr=N2Da/g

For similar gravity effects; Fr1=Fr2

3. Mass transfer: constant power per unit volume

For turbulent mixing with a geometrically similar system and approximately constant power number:

P=Np x ρ x n3 x Da5

For similar vessels; V  Da3

Therefore;
For constant power per unit volume; N3Da2=constant

Thus; NDa-2/3

And; x=2/3

4. Solids suspension: approximately x=3/4

Solids suspension is more complicated than single-phase liquid blending.

The objective is generally not just to mix the liquid but to achieve sufficient bottom clearance and suspension of particles.

A commonly used preliminary scale-up relationship is:

Therefore; x=3/4

This criteria is useful as an initial design/scale-up estimate for solids suspension, but actual suspension performance depends on several additional parameters, including; particle size and density, solids concentration, liquid viscosity and density, impeller type, impeller-to-tank diameter ratio, liquid height, tank geometry and required degree of suspension.

5. Constant tip speed: x=1

Tip speed is: Utip=π x Da x N

For constant tip speed; Da1 x N1=Da2 x N2

Therefore;

Hence; x=1

The important point is that constant tip speed does not mean constant power per unit volume. These criteria can give substantially different commercial-scale rpm.

To understand above concepts, consider the same system used in Part-1; pilot reactor of volume 50 L, impeller diameter 0.20 m and agitator speed is 285 rpm. Scale up this to commercial reactor of volume 6,250 L. Reactor is geometrically similar and impeller diameter is 1.0 m.

Let us solve this example, the linear scale factor is;Da2/Da1=(1.0/0.20) = 5

Using; N2/N1= (Da1/Da2) x

Appling these x factors we will obtain,

 

Scale-up criteria

X Factor

Commercial speed

Constant speed

0

285 rpm

Constant Froude number

0.5

127 rpm

Constant (P/V)

2/3

97 rpm

Solids suspension

3/4

85 rpm

Constant tip speed

1

57 rpm

 

Agitator scale-up is not about finding one perfect equation.

It is about identifying what must remain similar between the pilot and commercial reactor.

“Which exponent should I use?”. It is, “What physical phenomenon must my commercial reactor reproduce?”

Once that question is answered, the appropriate scale-up criterion becomes much easier to select.

Scale-up is successful when the larger reactor does not merely look like the pilot reactor—it performs like it where it matters.

Happy learning and happy mixing!

 