Agitator scale-up techniques – Part 2
Welcome curious minds!
In Part-1, we discussed the basic principles of agitator scale-up
and saw how criteria such as geometric similarity, constant tip speed, constant
torque per unit volume, and constant power per unit volume can be used to move
from a pilot reactor to a commercial reactor.
But there is an important question that often comes next; which
scale-up criterion should actually be used?
This is where agitator scale-up becomes more than just a
mathematical exercise.
A reactor may need fast blending, good surface circulation, mass
transfer, solids suspension, gas dispersion, or controlled shear. These
objectives do not respond to agitator speed in the same way.
Therefore, instead of simply saying “increase the vessel size
and reduce the rpm,” engineers often use a scale-up exponent to select an
appropriate agitator speed.
For geometrically similar vessels, agitator speed can be expressed
in the general form:
N2/N1= (Da1/Da2) x
Where; N1 - agitator speed at pilot scale
N2- agitator speed at
commercial scale
Da1- pilot impeller
diameter
Da2- commercial impeller
diameter
X - scale-up exponent
The value of x depends on what we are trying to preserve
during scale-up.
This is the key idea; different process objectives require
different relationships between impeller diameter and agitator speed.
How does the exponent change the agitator speed?
For the same increase in impeller diameter, changing x can produce
a very different commercial agitator speed.
Typical preliminary values are:
|
Process
objective |
Scale-up
basis |
Exponent
x |
|
Blending
/ mixing time |
Constant
N |
0 |
|
Surface
behaviour |
Constant
Froude number |
1/2 |
|
Mass
transfer / droplet size |
Constant
power per unit volume |
2/3 |
|
Solids
suspension |
Empirical
suspension criterion |
3/4 |
|
Constant
tip speed |
Constant
NDa |
1 |
1. Blending: constant agitator speed
For some blending applications, a simplified scale-up approach is
to maintain the same agitator speed; N2=N1. Therefore; x=0
However, keeping the same rpm as vessel size increases can
significantly increase tip speed, power demand, and mechanical loading.
Therefore, it should not be applied blindly.
2. Surface behaviour: Constant Froude number
When free-surface behaviour is important, such as in systems where
surface vortex formation or surface movement matters, the Froude number can be
considered, Fr=N2Da/g
For similar gravity effects; Fr1=Fr2
3. Mass transfer: constant power per unit volume
For turbulent mixing with a geometrically similar system and
approximately constant power number:
P=Np x ρ x n3 x Da5
For similar vessels; V Da3
Therefore;
For constant power per unit volume; N3Da2=constant
Thus; NDa-2/3
And; x=2/3
4. Solids suspension: approximately x=3/4
Solids suspension is more complicated than single-phase liquid
blending.
The objective is generally not just to mix the liquid but to
achieve sufficient bottom clearance and suspension of particles.
A commonly used preliminary scale-up relationship is:
Therefore; x=3/4
This criteria is useful as an initial design/scale-up estimate
for solids suspension, but actual suspension performance depends on several
additional parameters, including; particle size and density, solids
concentration, liquid viscosity and density, impeller type, impeller-to-tank
diameter ratio, liquid height, tank geometry and required degree of suspension.
5. Constant tip speed: x=1
Tip speed is: Utip=π x Da x N
For constant tip speed; Da1 x N1=Da2
x N2
Therefore;
Hence; x=1
The important point is that constant tip speed does not mean
constant power per unit volume. These criteria can give substantially different
commercial-scale rpm.
To understand above concepts, consider the same system used in
Part-1; pilot reactor of volume 50 L, impeller diameter 0.20 m and agitator
speed is 285 rpm. Scale up this to commercial reactor of volume 6,250 L.
Reactor is geometrically similar and impeller diameter is 1.0 m.
Let us solve this example, the linear scale factor is;Da2/Da1=(1.0/0.20) = 5
Using; N2/N1= (Da1/Da2)
x
Appling these x factors we will obtain,
|
Scale-up
criteria |
X Factor |
Commercial
speed |
|
Constant
speed |
0 |
285 rpm |
|
Constant
Froude number |
0.5 |
127 rpm |
|
Constant
(P/V) |
2/3 |
97 rpm |
|
Solids
suspension |
3/4 |
85 rpm |
|
Constant
tip speed |
1 |
57 rpm |
Agitator scale-up is not about finding one perfect equation.
It is about identifying what must remain similar between the pilot
and commercial reactor.
“Which exponent should I use?”. It is, “What physical phenomenon
must my commercial reactor reproduce?”
Once that question is answered, the appropriate scale-up criterion
becomes much easier to select.
Scale-up is successful when the larger reactor does not merely
look like the pilot reactor—it performs like it where it matters.
Happy learning and happy mixing!

Comments